Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
4.
Rev. bras. cir. cardiovasc ; 37(6): 942-944, Nov.-Dec. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1407334

ABSTRACT

ABSTRACT Inferior vena cava filter embolization is not uncommon and can reach 11.8%. However, device migration to the heart is not frequent and occurs in cases after inferior vena cava filter fracture. We present the case of a young woman who was submitted to a routine inferior vena cava filter placement three days before and presented with hemodynamic instability. Since the device was not retrievable, the surgical team opted for an open cardiac surgery under cardiopulmonary bypass to remove the inferior vena cava filter and avoid other further complications.

6.
Rev. bras. cir. cardiovasc ; 34(5): 630-632, Sept.-Oct. 2019. tab
Article in English | LILACS | ID: biblio-1042050

ABSTRACT

Abstract Heyde syndrome manifests as aortic stenosis associated with gastrointestinal bleeding. We describe the case of a 64-year-old man who came to the emergency room due to acute heart failure and intermittent gastrointestinal bleeding. Treatment involves initial correction of anemia and heart failure followed by aortic valve replacement. The prosthesis used depends on the characteristics of each patient and valve replacement allows the resolution of bleeding in most cases. Gastrointestinal bleeding in patients with aortic stenosis is associated with severity of the valve obstruction. A mechanical prosthesis was used with no recurrent bleeding even with the need for lifelong anticoagulation therapy.


Subject(s)
Humans , Male , Middle Aged , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Gastrointestinal Hemorrhage/surgery , Syndrome , Treatment Outcome
8.
Rev. bras. cir. cardiovasc ; 32(5): 347-353, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-897948

ABSTRACT

Abstract Introduction: The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. Objective: To compare patients with DDD and VDD pacemakers regarding the evolution of chronic atrial fibrillation (AF) and length of stay outside this postoperative arrhythmia. Methods: It was included 158 patients with dual chamber pacemakers, 48 DDD and 110 VDD. Follow-up period: between January 1, 1999 and December 31, 2015. The mean follow-up of patients with DDD was 5.35 years and the VDD, 4.74 years. The percentage of each group (DDD and VDD) which evolved to AF during follow-up was assessed. Also, it was made an actuarial study with the respective curves indicating the time free from AF for each group. Patients were classified according to the diagnosis that led to pacemaker implantation and the degree of heart failure. Results: The percentage of patients who developed AF was higher in DDD group (10.42%) than in VDD group (6.36%), but without statistical significance. Patients with DDD and VDD remained free of AF for similar period. Conclusion: Considering the results, the VDD pacemaker continues to be a good option to the DDD for routine use in cases properly indicated.


Subject(s)
Humans , Male , Female , Atrial Fibrillation/therapy , Cardiac Pacing, Artificial/methods , Time Factors , Actuarial Analysis , Follow-Up Studies
SELECTION OF CITATIONS
SEARCH DETAIL